Вход на сайт

Просмотр новости

Найдите то, что Вас интересует

DMU research with international partners reveals how and why some hip implants fail over time

Дата публикации: 31-03-2026 09:01:00

A DMU scientist has contributed to international research shedding new light on how and why some replacement hips fail.

Основное содержимое страницы с новостью.

A scientist from De Montfort University Leicester (DMU) has contributed to international research that sheds new light on how and why some types of hip replacements fail, and offering valuable insights that could improve patient outcomes and implant design.

Dr Fuad Khoshnaw, of DMU's School of Engineering, Infrastructure and Sustainability, worked with colleagues from Canada's University of Western Ontario, on the study called: Failure analysis of retrieved stainless steel Exeter hip implants: A fractographic and corrosion perspective.

The ground-breaking work, published in the Journal of Engineering Failure Analysis, used advanced engineering techniques - including a scanning electron microscope coupled with energy-dispersive X-ray spectroscopy, as well as high-powered digital microscopy - to analyse Exeter hips that had failed and been surgically removed from patients.

Exeter Hip

First used in 1970, the Exeter Hip is one of the world's most successful medical implants. It was designed by NHS surgeon Professor Robin Ling and University of Exeter engineer Clive Lee. It is currently used in around 40 per cent of all hip replacement operations in the UK; worldwide, more than two million people have received an Exeter hip.

Hip replacements are widely regarded as one of the most successful medical procedures, restoring mobility and quality of life for millions. However, a small number of implants can fail over time, requiring revision surgery; understanding why could be crucial for improving outcomes for patients.

The research focused on the combined effects of mechanical stress and corrosion inside the body - together know as known as 'corrosion fatigue'. In addition to mechanical fatigue, the team found that corrosion played a significant role. The body’s internal environment can gradually degrade stainless steel, particularly in areas where stress is concentrated. Corrosion fatigue was identified as a major contributor to implant failure.

Importantly, the research revealed that microscopic surface damage can act as a starting point for cracks. Once initiated, these cracks may grow slowly and remain undetected until they reach a critical size, potentially leading to sudden failure of the implant.

The findings have significant implications for both manufacturers and clinicians. Improving material selection, refining implant design, and enhancing surface finishing processes could reduce the likelihood of cracks forming. Better monitoring of patients with long-term implants may also help detect early signs of failure before serious complications occur.

Dr Khoshnaw said: “By examining real implants that have been used in patients, we can better understand how and why failures occur. This knowledge is essential for improving the design and durability of future hip replacements.”

Exeter hip2

Posted on Tuesday 31 March 2026

Схожие новости

#Наименование новостиТональностьИнформативностьДата публикации
1DMU research unlocks new understanding of vital life science substances05.7411-03-2026
2DMU research helps strengthen healthcare systems hit by climate change07.7917-06-2026
3DMU researchers join international quantum and AI initiative05.3829-05-2026
4Uterus transplants help women achieve successful pregnancies, analysis shows07.0627-09-2026
5New DMU research shows how AI soil monitoring could help farmers make every drop count in a warming world07.5631-07-2026
6DMU engineer paves way for the future of smart and powerful fabrics05.4303-09-2026
7DMU research uses grey-fuzzy framework to tackle 'black box' problem in AI predictions of rock permeability010.8804-08-2026
8Пациентке из Австрии поменяли тазобедренный сустав в необычных условиях08.106-10-2026
9У космонавтов после полётов дольше 90 дней чаще происходили переломы бедра010.0801-10-2026
103,000th robotic-assisted joint replacement completed at WVU Medicine Princeton Community Hospital Orthopedic Center08.102-10-2026

Классификация: Наука. Схожих патентов: 0. Схожих новостей: 10. Тональность: 0. Информативность: 5.85. Источник: www.dmu.ac.uk.